QIN-BREAST | QIN-BREAST
DOI: 10.7937/K9/TCIA.2016.21JUEBH0 | Data Citation Required | 536 Views | 9 Citations | Image Collection
Location | Species | Subjects | Data Types | Cancer Types | Size | Status | Updated | |
---|---|---|---|---|---|---|---|---|
Breast | Human | 67 | CT, MR, PT, Classification | Breast Cancer | Clinical | Public, Complete | 2020/01/10 |
Summary
This collection contains longitudinal PET/CT and quantitative MR images collected for the purpose of studying treatment assessment in breast cancer in the neoadjuvant setting. Images were acquired at three time points: prior to the start of treatment (t1), after the first cycle of treatment (t2), and either after the second cycle of treatment or at the completion of all treatments (prior to surgery) (t3). The PET/CT images were acquired with a support device built in-house to allow the patient to be in the prone position to facilitate registration with the MRI data. The value of this collection is to provide clinical imaging data for the development and evaluation of quantitative imaging methods for treatment assessment early in the course of therapy for breast cancer. Data is provided by Vanderbilt University, PI Dr. Thomas E. Yankeelov. PET/CT data were acquired with a GE Discovery STE scanner (GE Healthcare, Waukesha, WI, USA). A low-mAs CT scan was acquired for attenuation correction of the emission data. The acquisition parameters for the transmission CT scan were the following: the tube current was 80 mAs for a 70-kg patient and scaled accordingly for all patients, the tube voltage was 120 KVp, and the pitch was 1.675/1. The activity of FDG administered was approximately 370 MBq (10 mCi) for a 70-kg patient and scaled according to weight. FDG was administered intravenously via an antecubital vein contra-lateral to the affected breast. After 60 min, emission data was collected in 3D mode for 2 min per bed position. The emission scan was first collected in the prone position over the breast only, and then in the supine position from the skull to mid-femurs. Standard-of-care supine images and research prone images were acquired at times t1 and t3, while only the prone images were acquired at t2. The MRI data consist of diffusion-weighted images (DWIs), dynamic contrast-enhanced (DCE) images, and multi-flip data for T1-mapping. The MRIs were obtained using a dedicated 16-channel bilateral breast coil at 3.0T (Philips Achieva with the MammoTrak table). DWIs were acquired with a single-shot spin echo (SE) echo planar imaging (EPI) sequence in three orthogonal diffusion encoding directions (x, y, and z). For 14 patients, b = 0 and 500 s/mm2, TR/TE = 2500 ms/45 ms Δ = 21.4 ms, δ = 10.3 ms and 10 signal acquisitions were acquired. For 19 patients, b = 0 and 600 s/mm2, TR/TE = “shortest” (range = 1800 - 3083 ms/43 - 60 ms) Δ = 20.7 - 29 ms, δ = 11.4 - 21 ms and 10 signal acquisitions were acquired. For four patients, b = 50 and 600 s/mm2 for two patients), TR/TE = “shortest” (range = 1840 - 3593 ms/43 - 60 ms) Δ = 20.6 - 29 ms, δ = 11.5 - 21 ms and 10 signal acquisitions were acquired. Prior to the DCE-MRI acquisition, data for constructing a T1 map were acquired with an RF-spoiled 3D gradient echo multi-flip angle approach with ten flip angles from 2 to 20 degrees in 2o increments. For both the T1 map and DCE scans, TR = 7.9 ms, TE = 4.6 ms, and the acquisition matrix was 192x192x20 (full-breast) over a sagittal square field of view (22 cm2) with slice thickness of 5 mm. For the DCE study, each 20-slice set was collected in 16 seconds at 25 time points for just under seven minutes of dynamic scanning. A catheter placed within an antecubital vein delivered 0.1 mmol/kg (9 – 15 mL, depending on patient weight) of gadopentetate dimeglumine, Gd-DTPA, (Magnevist, Wayne, NJ) at 2 mL/sec (followed by a saline flush) via a power injector (Medrad, Warrendale, PA) after the acquisition of the first three dynamic scans (baseline). An extension of this QIN-BREAST collection is available via the QIN-BREAST-02 collection. It contains updated scan protocols and data collected at both Vanderbilt University Medical Center and the University of Chicago to demonstrate similar results at multiple sites (both using Philips 3T MR scanners). The mission of the QIN is to improve the role of quantitative imaging for clinical decision making in oncology by developing and validating data acquisition, analysis methods, and tools to tailor treatment for individual patients and predict or monitor the response to drug or radiation therapy. More information is available on the Quantitative Imaging Network Collections page. Interested investigators can apply to the QIN at: Quantitative Imaging for Evaluation of Responses to Cancer Therapies (U01) PAR-11-150.QIN-BREAST-02 Multi-center Study
About the NCI QIN
Data Access
Version 2: Updated 2020/01/10
Lifted “Restricted access” embargo. No changes to files were required.
Title | Data Type | Format | Access Points | Subjects | License | |||
---|---|---|---|---|---|---|---|---|
Images | CT, MR, PT | DICOM | Download requires NBIA Data Retriever |
68 | 216 | 536 | 102,451 | CC BY 3.0 |
QIN-Breast Treatment Response | Classification | XLSX | CC BY 3.0 |
Additional Resources for this Dataset
The NCI Cancer Research Data Commons (CRDC) provides access to additional data and a cloud-based data science infrastructure that connects data sets with analytics tools to allow users to share, integrate, analyze, and visualize cancer research data.
- Imaging Data Commons (IDC) (Imaging Data)
- IDC Zenodo community dataset: Image segmentations produced by BAMF under the AIMI Annotations initiative
Citations & Data Usage Policy
Data Citation Required: Users must abide by the TCIA Data Usage Policy and Restrictions. Attribution must include the following citation, including the Digital Object Identifier:
Data Citation |
|
Li, X., Abramson, R. G., Arlinghaus, L. R., Chakravarthy, A. B., Abramson, V. G., Sanders, M., & Yankeelov, T. E. (2016). Data From QIN-BREAST (Version 2) [Data set]. The Cancer Imaging Archive. https://doi.org/10.7937/K9/TCIA.2016.21JUEBH0 |
Detailed Description
Treatment Response information: QIN-Breast_TreatmentResponse(2014-12-16).xlsx
Related Publications
Publications by the Dataset Authors
The authors recommended the following as the best source of additional information about this dataset:
Publication Citation |
|
Li X, Abramson RG, Arlinghaus LR, Kang H, Chakravarthy AB, Abramson VG, Farley J, Mayer IA, Kelley MC, Meszoely IM, Means-Powell J, Grau AM, Sanders M, Yankeelov TE. Multiparametric magnetic resonance imaging for predicting pathological response after the first cycle of neoadjuvant chemotherapy in breast cancer. Investigative Radiology, 2015 Apr;50(4):195-204. PMCID: PMC4471951 |
No other publications were recommended by dataset authors.
Research Community Publications
TCIA maintains a list of publications that leveraged this dataset. If you have a manuscript you’d like to add please contact TCIA’s Helpdesk.
Previous Versions
Version 1: Updated 2015/09/04
Title | Data Type | Format | Access Points | License | ||||
---|---|---|---|---|---|---|---|---|
Images | DICOM | Download requires NBIA Data Retriever |
||||||
QIN-Breast Treatment Response | XLS |