Skip to main content

QIN-PROSTATE

The Cancer Imaging Archive

QIN PROSTATE | QIN PROSTATE

DOI: 10.7937/K9/TCIA.2016.fADs26kG | Data Citation Required | 174 Views | 10 Citations | Image Collection

Location Species Subjects Data Types Cancer Types Size Status Updated
Prostate Human 22 MR Prostate Cancer 4.72GB Limited, Complete 2014/07/02

Summary

This collection contains multiparametric MRI images collected for the purposes of detection and/or staging of prostate cancer. The MRI parameters include T1- and T2-weighted sequences as well as Diffusion Weighted and Dynamic Contrast-Enhanced MRI. The images were obtained using endorectal and phased array surface coils at 3.0T (GE Signa HDx 15.0) The value of this collection is to provide clinical image data for the development and evaluation of quantitative methods for prostate cancer characterization using multiparametric MRI.  Data was provided by Brigham and Women's Hospital, PI Dr. Fiona Fennessy.MR imaging exam was performed on a GE Signa HDx 3.0 T magnet (GE Healthcare, Waukesha, WI) using a combination of 8-channel abdominal array and endorectal coil (Medrad, Pittsburgh, PA). The MR sequences included T1- and T2-weighted imaging, diffusion weighted (DW) imaging, and DCE MRI. T1-weighted imaging was performed with a spoiled gradient recalled echo (SPGR) sequence with TR/TE/α = 385 ms/6.2 ms/65° over a (16 cm)2 field of view (FOV). T2-weighted imaging was performed with a FRFSE (Fast Recovery Fast Spin Echo) sequence with TR/TE = 3500/102 ms, FOV = (16 cm)2. A DW echo planar imaging sequence with trace diffusion sensitization and b-values of 0 and 500 s/mm2, and TR/TE = 2500/65 ms provided data for an Apparent Diffusion Coefficient (ADC) map. Finally, DCE MRI utilized a 3D SPGR sequence with TR/TE/α = 3.6 ms/1.3 ms/15°, FOV = (26 cm)2, with full gland coverage and reconstructed image voxel size of 1×1×6 mm (interpolated to 256×256 matrix). DCE MRI frames were acquired at approximately 5 s intervals (the number of frames varied between 12 and 16 slices resulting in the time resolution between 4.4 and 5.3 seconds) to achieve a clinically appropriate compromise between spatial and temporal resolutions. Gadopentetate dimeglumine (Magnevist, Berlex Laboratories, Wayne, New Jersey) was injected intravenously using a syringe pump (0.15 mmol/kg) at the rate of 3 ml/s followed by 20 ml saline flush at the same rate. The protocol included ~ 5 baseline scans prior to contrast injection for estimation of baseline tissue properties.

About the NCI QIN

The mission of the QIN is to improve the role of quantitative imaging for clinical decision making in oncology by developing and validating data acquisition, analysis methods, and tools to tailor treatment for individual patients and predict or monitor the response to drug or radiation therapy. More information is available on the Quantitative Imaging Network Collections page. Interested investigators can apply to the QIN at: Quantitative Imaging for Evaluation of Responses to Cancer Therapies (U01) PAR-11-150.

Data Access

When you have a TCIA account, please email to help@cancerimagingarchive.net to request access to these data.

Version 1: Updated 2014/07/02

Title Data Type Format Access Points Subjects Studies Series Images License
Images MR DICOM
Download requires NBIA Data Retriever
22 22 319 25,981 TCIA Limited (contact Support)
Related Datasets
No related Analysis Results found: Submit your proposal! No related Collections found
Legend: Analysis Results| Collections

Citations & Data Usage Policy

Data Citation Required: Users must abide by the TCIA Data Usage Policy and Restrictions. Attribution must include the following citation, including the Digital Object Identifier:

Data Citation

Fedorov A, Tempany C, Mulkern R, & Fennessy F. (2016). Data From QIN PROSTATE. The Cancer Imaging Archive. DOI: 10.7937/K9/TCIA.2016.fADs26kG

Detailed Description

A subset of datasets from this collection were used in [1]. The MR sequences included T1– and T2-weighted imaging, diffusion weighted (DW) imaging, and DCE MRI following the protocol described in [2].

References

[1] Fedorov, A., Fluckiger, J., Ayers, G. D., Li, X., Gupta, S. N., Tempany, C., Mulkern, R., Yankeelov, T.E., Fennessy, F. M. (2014). A comparison of two methods for estimating DCE-MRI parameters via individual and cohort based AIFs in prostate cancer: A step towards practical implementation. Magnetic Resonance Imaging, 32(4), 321–9. doi:10.1016/j.mri.2014.01.004

[2] Hegde, J. V, Mulkern, R. V, Panych, L. P., Fennessy, F. M., Fedorov, A., Maier, S. E., & Tempany, C. M. C. (2013). Multiparametric MRI of prostate cancer: An update on state-of-the-art techniques and their performance in detecting and localizing prostate cancer. Journal of Magnetic Resonance Imaging : JMRI37(5), 1035–54. doi:10.1002/jmri.23860

Related Publications

Publications by the Dataset Authors

The authors recommended the following as the best source of additional information about this dataset:

Publication Citation

Fedorov A, Fluckiger J, Ayers GD, Li X, Gupta SN, Tempany C, Mulkernag R, Yankeelov TE, Fennessy FM. (2014). A comparison of two methods for estimating DCE-MRI parameters via individual and cohort based AIFs in prostate cancer: A step towards practical implementation. Magnetic Resonance Imaging 32(4):321-329. DOI:  10.1016/j.mri.2014.01.004

Publication Citation

Hegde, J. V., Mulkern, R. V., Panych, L. P., Fennessy, F. M., Fedorov, A., Maier, S. E., & Tempany, C. M. C. (2013, April 18). Multiparametric MRI of prostate cancer: An update on state-of-the-art techniques and their performance in detecting and localizing prostate cancer. J. Magn. Reson. Imaging. Wiley-Blackwell. http://doi.org/10.1002/jmri.23860

No other publications were recommended by dataset authors.

Publication Citation

Fedorov A, Fluckiger J, Ayers GD, Li X, Gupta SN, Tempany C, Mulkernag R, Yankeelov TE, Fennessy FM. (2014). A comparison of two methods for estimating DCE-MRI parameters via individual and cohort based AIFs in prostate cancer: A step towards practical implementation. Magnetic Resonance Imaging 32(4):321-329. DOI:  10.1016/j.mri.2014.01.004

Publication Citation

Hegde, J. V., Mulkern, R. V., Panych, L. P., Fennessy, F. M., Fedorov, A., Maier, S. E., & Tempany, C. M. C. (2013, April 18). Multiparametric MRI of prostate cancer: An update on state-of-the-art techniques and their performance in detecting and localizing prostate cancer. J. Magn. Reson. Imaging. Wiley-Blackwell. http://doi.org/10.1002/jmri.23860

Research Community Publications

TCIA maintains a list of publications which leverage our data. If you have a manuscript you’d like to add please contact TCIA’s Helpdesk.

TCIA maintains a list of publications that leveraged this dataset. If you have a manuscript you’d like to add please contact TCIA’s Helpdesk.

Other Publications Using this Data

TCIA maintains a list of publications which leverage our data. If you have a manuscript you’d like to add please contact TCIA’s Helpdesk.